High-performance IR Radiator
- Size Guide
Size Guide
DRESSEST-SHIRTBOTTOMSDRESSESSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
T-SHIRTSize Chest Waist Hips 2XS 32 26 32 XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 All measurements are in INCHES
and may vary a half inch in either direction.
BOTTOMSSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
- Delivery & Return
Delivery
Store delivery FREE
1-3 working days
Home or collection point from £35.00 FREE
On all your orders for home or collection point delivery
Returns
Return
We will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period).
Returns in store FREE
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
The IR radiator is a high-power IR device, used to receive the carrier signal from the IR transmitting controller, and transmit the carrier signal through infrared rays. It supports hand-in-hand connection mode, and up to 30 radiating panels can be connected at the same time.
Feature:
* Strong signal transmitting ability, the maximum distance can reach 25 meters; realize 500 meters transmission distance after cascading.
* Transmitting angle: 135°.
* Cable delay compensation functions.
* The standby function: the IR radiator will enter into standby status when there is no signal received, or there is no signal output from the controller. The standby power is 3W.
* The radiation intensity can reduce by half. Reduce signal power, easy to use in small spaces.
* The arc structure enables large radiation angle and wide radiation coverage.
Specification:
Model | TS-0370HS | ||||||||||||||||||||||||||
Input voltage | 100V-240V 50/60Hz | ||||||||||||||||||||||||||
Rated power | 36W | ||||||||||||||||||||||||||
Frequency range | 2MHz~6MHz | ||||||||||||||||||||||||||
IR radiant power | 33W | ||||||||||||||||||||||||||
RF output impedance | 75Ω | ||||||||||||||||||||||||||
RF input | 100mV-3V 10KΩ | ||||||||||||||||||||||||||
Gain control | AGC automatic gain control | ||||||||||||||||||||||||||
Automatic threshold control | 100mV RF signal start | ||||||||||||||||||||||||||
Standby power consumption | 3W | ||||||||||||||||||||||||||
Color | Black | ||||||||||||||||||||||||||
Dimension | 478×228×208mm (L×W×H) | ||||||||||||||||||||||||||
Weight | 5.3Kg
The IR radiator is a high-power IR device, used to receive the carrier signal from the IR transmitting controller, and transmit the carrier signal through infrared rays. It supports hand-in-hand connection mode, and up to 30 radiating panels can be connected at the same time. Feature: * Strong signal transmitting ability, the maximum distance can reach 25 meters; realize 500 meters transmission distance after cascading. * Transmitting angle: 135°. * Cable delay compensation functions. * The standby function: the IR radiator will enter into standby status when there is no signal received, or there is no signal output from the controller. The standby power is 3W. * The radiation intensity can reduce by half. Reduce signal power, easy to use in small spaces. * The arc structure enables large radiation angle and wide radiation coverage. Specification:
|
5 |
|
0 |
4 |
|
0 |
3 |
|
0 |
2 |
|
0 |
1 |
|
0 |
Related Products
The Hochiki PE series of power supplies is designed to provide the power and flexibility needed for the most demanding fire
system installations. The PE-10SN is a 10 Amp 24Vdc switch mode power supply design which is up to 50% more efficient than
linear mode supplies the PE series is your best choice for powering fire system notification appliances and accessories. New
and retrofit construction requirements for ADA compliance are easily accomplished with ample power for additional notification
appliances along with the ability to synchronize the notification appliances using built in sync generation for Potter, System
Sensor ®, Gentex® and Wheelock ® notification appliances. The PE series goes even further to make retrofits easier with the
advanced QuadraSync feature which allows notification appliances from different manufacturers to sync with each other. You
also have the option to monitor an existing circuit by placing a reference resistor of the same value on the power supply and
continuing to monitor the circuit without changing the field EOL.
- HOCHIKI FNP-1127-SLC – Single Slc Loop Expander Card (Firenet Plus Only)
- #1 Supplier for Fire Safety Equipment in North America. Our company is dedicated to help and supply your fire equipment needs with the best prices Worldwide.
- We have the most dedicated customer service team to help you with any question regarding our products and your orders.
Key Features
- Model: LBD0606/10
- Frequency: 150Hz -15KHz
- Input Voltage: 70V to 100V
- Material: Metal
- Weight: 750 g
100 in stock
STANDARD FEATURES
L@ti-View works with L@titude, FireNET and
FireNET Plus panels.
Reports configuration mismatch errors –
ensuring that the graphics system is properly
maintained and updated whenever there are
any panel configuration revisions
Powerful event log filtering and reporting
Manage the state of the fire system using a
combination of graphical images and system
controls
Programmable macro buttons to perform panel
control operations
Full map navigation using configurable buttons
or map areas
Device analog value reporting
Perform device and zone disablements /
enablements
Operate and restore loop output devices for
testing purposes
Dual screen support for clarity
- Extended monitoring area
- Transmitter, receiver, and evaluating unit integrated into a compact housing
- Electronic help for detector alignment and automatic detector calibration procedure
- Automatic compensation for contamination
- LED display in control unit for various operating states
- Adjustable alarm thresholds
75 in stock
Product Code: 0500-05890
The Hochiki HEH Series Horn
99 in stock
- Make: Hochiki America
- Model code: ALN-V
- Type: Smoke
- Style: Photoelectric
- Hochiki America is a photoelectric smoke sensor with the following features: • Low profile – Only 2.00″ high, including base• Simple and reliable device addressing• Automatic compensation for sensor contamination• Built-in fire
Model TS-0310/ TS-0310A
Microphone type Electret condenser microphone
Microphone directivity Cardioid F
requency response 80Hz~16KHz
38 in stock
Analogue Addressable Smoke detector
Country of Origin: GERMANY
Categories: Addressable Fire Alarm System, Fire Alarm System, Smoke/Heart Detector
Product Code: FN-4127-NIC (0100-03190)
STANDARD FEATURES
Low profile – only 2.00″ high, including base
Simple and reliable device addressing method
Uses the noise immune Digital Communication
Protocol (DCP), which utilizes interrupts for fast
response to fires
Rate of rise temperature threshold = 15°F/Min
(determined by panel)
Adjustable threshold temperature = 135°F – 190°F
(determined by panel)
UL maximum spacing of 70 feet
Reliable operation, even if the lens is contaminated by a film of oil, dust, water vapor or ice MOD. 016589