ADDRESSABLE_DUAL_OPTICAL_SMOKE_DETECTOR 7
Analogue Addressable Smoke detector
Country of Origin: GERMANY
Categories: Addressable Fire Alarm System, Fire Alarm System, Smoke/Heart Detector
- Size Guide
Size Guide
DRESSEST-SHIRTBOTTOMSDRESSESSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
T-SHIRTSize Chest Waist Hips 2XS 32 26 32 XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 All measurements are in INCHES
and may vary a half inch in either direction.
BOTTOMSSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
- Delivery & Return
Delivery
Store delivery FREE
1-3 working days
Home or collection point from £35.00 FREE
On all your orders for home or collection point delivery
Returns
Return
We will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period).
Returns in store FREE
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
- Highly reliable and accurate thanks to Intelligent Signal Processing (ISP)
- Earliest detection of lightest smoke with dual-optical versions (Dual-Ray technology)
- Monitors environment for electromagnetic influence for fast root-cause analysis
- Automatic and manual address setting
Functions
Sensor technology and signal processing
The individual sensors can be configured in the FSP-5000-RPS programming software.
All sensor signals are analysed continuously by the internal evaluation electronics (ISP – Intelligent Signal Processing) and are linked with each other via an inbuilt microprocessor. The link between the sensors means that the combined detectors can also be used where light smoke, steam or dust must be expected during the course of normal operation.
Only if the signal combination corresponds to the characteristics of the application site, selected during the programming, the alarm is triggered automatically. This results in less false alarms.
In addition, the time of the sensor signals on fire and fault detection is analysed, which leads to high detection reliability for each individual sensor.
In the case of the optical and chemical sensor, the response threshold (drift compensation) is actively adjusted. Manual or time-controlled switch-off of individual sensors is possible for adjustment to extreme interference factors.
Optical sensor (smoke sensor)
The optical sensor uses the scattered-light method. An LED transmits light to the measuring chamber, where it is absorbed by the labyrinth structure. In the event of a fire, smoke enters the measuring chamber and the smoke particles scatter the light from the LED. The amount of light hitting the photo diode is converted into a proportional electrical signal.
The dual-optical versions use two optical sensors with different wavelengths. The Dual-Ray technology works with an infrared and a blue LED so that lightest smoke is detected fast and reliably (TF1 and TF9 detection).
Thermal sensor (temperature sensor)
A thermistor in a resistance network is used as a thermal sensor from which an analog-digital converter measures the temperature-dependent voltage at regular intervals.
Depending on the specified detector class, the temperature sensor triggers the alarm status when the maximum temperature of 54 °C or 69 °C is exceeded
Technical specifications
Electrical
Operating voltage | 15 V DC to 33 V DC | |||
Current consumption | < 0.55 mA | |||
Alarm output | Per data word by two-wire | |||
signal line | ||||
Indicator output | Open collector connects 0 V | |||
over 1.5 kΩ through, max. | ||||
15 mA | ||||
Mechanics | ||||
Dimensions | ||||
• | Without base | Ø 99.5 x 52 mm | ||
• | With base | Ø 120 x 63.5 mm | ||
Housing | ||||
• | Material | Plastic, ABS (Novodur) | ||
• | Color | White, similar to RAL 9010, | ||
matt finish | ||||
Weight | Without / With packaging | |||
• | FAP-425-DOTC-R | Approx. 85 g / Approx. 130 g | ||
• FAP-425-DO-R, | Approx. 80 g / Approx. 120 g | |||
FAP-425-DOT-R | ||||
• FAP-425-O-R, | Approx. 80 g / Approx. 120 g | |||
FAP-425-OT-R, | ||||
FAH-425-T-R | ||||
• | FAP-425-O, FAP-425-OT | Approx. 75 g / Approx. 115 g | ||
Environmental conditions | ||||
Permissible operating temperature | ||||
• FAP-425-DOTC-R | -10°C to +50°C | |||
• FAP-425-DOT-R, | -20°C to +50°C | |||
FAP-425-OT-R, | ||||
FAH-425-T-R, | ||||
FAP-425-OT | ||||
• FAP-425-DO-R, | -20°C to +65°C | |||
FAP-425-O-R, | ||||
FAP-425-O | ||||
Permissible storage temperature | ||||
• FAP-425-DOTC-R | -20°C to +50 °C | |||
• All versions (except for | -25°C to +80°C | |||
FAP-425-DOTC-R) | ||||
Permissible relative humidity | 95% (non-condensing) | |||
Permissible air speed | 20 m/s. | |||
Degree of protection (IEC 60529) | IP41 , | |||
IP43 with detector base and | ||||
FAA-420-SEAL or MSC 420 | ||||
Further characteristics | ||||
Response sensitivity | ||||
• | Optical part | In accordance with EN 54-7 | ||
(programmable) | ||||
• | Thermal maximum part | > 54°C / > 69°C | ||
• | Thermal differential part: | A2S / A2R / A1 / A1R / BS / | ||
• | FAH-425-T-R | BR, in line with EN 54‑5 | ||
(programmable) | ||||
• | Thermal differential part: | A2S / A2R / BS / BR, in line | ||
• FAP-425-DOTC-R, | with EN 54-5 (programmable) | |||
FAP-425-DOT-R, | ||||
FAP-425-OT-R, | ||||
FAP-425-OT | ||||
• | Gas sensor | In ppm range | ||
Individual display | LED red and green | |||
Color code | ||||
• FAP-425-O-R, | No marking | |||
FAP-425-O | ||||
5 |
|
0 |
4 |
|
0 |
3 |
|
0 |
2 |
|
0 |
1 |
|
0 |
Related Products
STANDARD FEATURES
L@ti-View works with L@titude, FireNET and
FireNET Plus panels.
Reports configuration mismatch errors –
ensuring that the graphics system is properly
maintained and updated whenever there are
any panel configuration revisions
Powerful event log filtering and reporting
Manage the state of the fire system using a
combination of graphical images and system
controls
Programmable macro buttons to perform panel
control operations
Full map navigation using configurable buttons
or map areas
Device analog value reporting
Perform device and zone disablements /
enablements
Operate and restore loop output devices for
testing purposes
Dual screen support for clarity
Usage/Application |
Industrial
|
Number of Zone |
10
|
Material |
Sheet Metal
|
Operating Voltage |
24 V DC
|
Material |
Plastic
|
Usage/Application |
Office Buildings
|
Power Source |
Electric
|
Automation Grade |
Semi-Automatic
|
Voltage |
24 V
|
Frequency |
50 Hz
|
Weight |
300 gm
|
Model Number |
FAS-420
|
- High deceptive alarm immunity with intelligent signal processing LOGIC·SENS
- Innovative airflow monitoring including single-hole monitoring detects obstruction and breakage
- Initial set-up made easy by automatic initialization
- Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators
- SL-versions: Noise reduction to 38 dB(A) by extremely quiet fan and up to 34 dB(A) with additional sound absorber
SKU: S758Category: Taktis Panels
Tags: fire alarm control panel, kentec taktis
- • UL & ULC Listed
• Designed for use with all NS analog sensors
• Available in 4 and 6 inch models
• Contains a security locking tab for tamper protection
ITC T-774H Wall Mount Loud Speaker Specs:
Model | T-774HW |
Power Taps @100V | 2.5W, 5W, 10W, 20W |
Power Taps @70V | 1.25W, 2.5W, 5W, 10W, 20W |
Transformer Impedance | 4KΩ/2KΩ/1KΩ/500Ω/250Ω |
Input | 70V/100V/8Ω |
SPL(1W/1M) | 86dB |
Max. SPL (Rated W/1M) | 99dB |
Frequency Response (-10dB) | 120-18KHz |
Finish | Baffle: ABS, Black/White Grille: Steel, Black/White |
Speaker Driver | 4″ x 1 1.5″ x 1 |
Dimension | 260 x 170 x 170mm |
Weight | 2.3kg |
Mounting | With mounting bracket fixed by screw |
99 in stock
STANDARD FEATURES
Low profile – only 2.00″ high, including base
Simple and reliable device addressing method
Uses the noise immune Digital Communication
Protocol (DCP), which utilizes interrupts for fast
response to fires
Rate of rise temperature threshold = 15°F/Min
(determined by panel)
Adjustable threshold temperature = 135°F – 190°F
(determined by panel)
UL maximum spacing of 70 feet
Product Code: FN-4127-NIC (0100-03190)
- Integrated control unit
- Auto-Alignment with motorized detector head
- Light Cancellation Technology
- Building Movement Tracking
- Detection range up to 393 ft
100 in stock
Bosch BCM-0000-B Battery Controller Module monitors the power supply of the fire panel and the charging of the batteries
The DCP-AMS are the Hochiki America series of addressable manual pull stations that provide a fast and practical means of manually initiating a fire alarm signal. Both single action and dual action manual pull stations are available. Resetting of the pull station requires either a 1/8″ hex key.
99 in stock
Reviews
There are no reviews yet.