Dual SLC Panel Module-S758_asian-technologies-ltd
SKU: S758Category: Taktis Panels
Tags: fire alarm control panel, kentec taktis
- Size Guide
Size Guide
DRESSEST-SHIRTBOTTOMSDRESSESSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
T-SHIRTSize Chest Waist Hips 2XS 32 26 32 XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 All measurements are in INCHES
and may vary a half inch in either direction.
BOTTOMSSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
- Delivery & Return
Delivery
Store delivery FREE
1-3 working days
Home or collection point from £35.00 FREE
On all your orders for home or collection point delivery
Returns
Return
We will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period).
Returns in store FREE
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
Dual Loop Panel Module
The Dual Loop Panel Module provides two supervised loop functions for the fire alarm control panel. All models of the Taktis Fire Alarm Control Panel contain at least one Dual Loop Panel Module.
The Dual Loop Panel Module monitors loop device status and provides status to the panel processor. It holds device configurations and operates in a standalone manner when catastrophic failures occur. The Dual Loop Panel Modules can be connected in any available slot (C-K) on the Main Back Board to provide this operating function.
Each Dual Loop Panel Module can support either Hochiki or Apollo protocols.
Product code : S758
Technical information
- Supply Voltage 24 V DC
- Loop Voltage Range 25 – 38 V DC
- Maximum Loop Current 400 mA
- Maximum Current Consumption 1.5 A
- Protocol(s) Supported Hochiki
- Temperature Range -5oC – 49oC or 23oF – 120oF
- Relative Humidity Up to 95%, non-condensing
5 |
|
0 |
4 |
|
0 |
3 |
|
0 |
2 |
|
0 |
1 |
|
0 |
Related Products
Analogue Addressable Smoke detector
Country of Origin: GERMANY
Categories: Addressable Fire Alarm System, Fire Alarm System, Smoke/Heart Detector
- • UL & ULC Listed
• Designed for use with all NS analog sensors
• Available in 4 and 6 inch models
• Contains a security locking tab for tamper protection
Key Features
- Model: LBD0606/10
- Frequency: 150Hz -15KHz
- Input Voltage: 70V to 100V
- Material: Metal
- Weight: 750 g
100 in stock
Material |
Plastic
|
Usage/Application |
Office Buildings
|
Power Source |
Electric
|
Automation Grade |
Semi-Automatic
|
Voltage |
24 V
|
Frequency |
50 Hz
|
Weight |
300 gm
|
Model Number |
FAS-420
|
- High deceptive alarm immunity with intelligent signal processing LOGIC·SENS
- Innovative airflow monitoring including single-hole monitoring detects obstruction and breakage
- Initial set-up made easy by automatic initialization
- Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators
- SL-versions: Noise reduction to 38 dB(A) by extremely quiet fan and up to 34 dB(A) with additional sound absorber
- Extended monitoring area
- Transmitter, receiver, and evaluating unit integrated into a compact housing
- Electronic help for detector alignment and automatic detector calibration procedure
- Automatic compensation for contamination
- LED display in control unit for various operating states
- Adjustable alarm thresholds
75 in stock
The Hochiki PE series of power supplies is designed to provide the power and flexibility needed for the most demanding fire
system installations. The PE-10SN is a 10 Amp 24Vdc switch mode power supply design which is up to 50% more efficient than
linear mode supplies the PE series is your best choice for powering fire system notification appliances and accessories. New
and retrofit construction requirements for ADA compliance are easily accomplished with ample power for additional notification
appliances along with the ability to synchronize the notification appliances using built in sync generation for Potter, System
Sensor ®, Gentex® and Wheelock ® notification appliances. The PE series goes even further to make retrofits easier with the
advanced QuadraSync feature which allows notification appliances from different manufacturers to sync with each other. You
also have the option to monitor an existing circuit by placing a reference resistor of the same value on the power supply and
continuing to monitor the circuit without changing the field EOL.
The DCP-AMS are the Hochiki America series of addressable manual pull stations that provide a fast and practical means of manually initiating a fire alarm signal. Both single action and dual action manual pull stations are available. Resetting of the pull station requires either a 1/8″ hex key.
99 in stock
- Integrated control unit
- Auto-Alignment with motorized detector head
- Light Cancellation Technology
- Building Movement Tracking
- Detection range up to 393 ft
Reliable operation, even if the lens is contaminated by a film of oil, dust, water vapor or ice MOD. 016589
Model TS-0310/ TS-0310A
Microphone type Electret condenser microphone
Microphone directivity Cardioid F
requency response 80Hz~16KHz
38 in stock
Bosch BCM-0000-B Battery Controller Module monitors the power supply of the fire panel and the charging of the batteries
Reviews
There are no reviews yet.