L@TI-VIEW GRAPHICS APPLICATION
STANDARD FEATURES
L@ti-View works with L@titude, FireNET and
FireNET Plus panels.
Reports configuration mismatch errors –
ensuring that the graphics system is properly
maintained and updated whenever there are
any panel configuration revisions
Powerful event log filtering and reporting
Manage the state of the fire system using a
combination of graphical images and system
controls
Programmable macro buttons to perform panel
control operations
Full map navigation using configurable buttons
or map areas
Device analog value reporting
Perform device and zone disablements /
enablements
Operate and restore loop output devices for
testing purposes
Dual screen support for clarity
- Size Guide
Size Guide
DRESSEST-SHIRTBOTTOMSDRESSESSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
T-SHIRTSize Chest Waist Hips 2XS 32 26 32 XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 All measurements are in INCHES
and may vary a half inch in either direction.
BOTTOMSSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
- Delivery & Return
Delivery
Store delivery FREE
1-3 working days
Home or collection point from £35.00 FREE
On all your orders for home or collection point delivery
Returns
Return
We will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period).
Returns in store FREE
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
This professional-grade graphics system will
complement the new generation of fire alarm
control panels, while also being backwardcompatible with the current analog product.
L@ti-View enables the creation of a 2D map of
any site or building to monitor fire safety and
detection, and automatically switches to an area
where a fire device has been activated to allow
immediate viewing and investigation of an event.
It also displays the relevant emergency assembly
and fire control points.
Fully-configurable on-site, L@ti-View supports
dual screens allowing a dedicated screen for the
2D graphic map and a separate screen for system
management. It also reports any configuration
errors, ensuring that the graphics system is
maintained and updated whenever the panel
configuration is revised.
PC REQUIREMENTS
Processor CPU Intel® Core™ i5 64 bit CPU
RAM 16 GB
Hard Drive Size 500 MB
Display 1280 x 768
Ports USB 2.0, and Ethernet (L@titude). An additional USB 2.0 port is required for a FireNET
Panel.
Operating System Windows 10 Pro 64 bit
Internet Connection Internet connectivity is necessary to perform updates and to take advantage of some
features
5 |
|
0 |
4 |
|
0 |
3 |
|
0 |
2 |
|
0 |
1 |
|
0 |
Related Products
- • UL & ULC Listed
• Designed for use with all NS analog sensors
• Available in 4 and 6 inch models
• Contains a security locking tab for tamper protection
The Hochiki PE series of power supplies is designed to provide the power and flexibility needed for the most demanding fire
system installations. The PE-10SN is a 10 Amp 24Vdc switch mode power supply design which is up to 50% more efficient than
linear mode supplies the PE series is your best choice for powering fire system notification appliances and accessories. New
and retrofit construction requirements for ADA compliance are easily accomplished with ample power for additional notification
appliances along with the ability to synchronize the notification appliances using built in sync generation for Potter, System
Sensor ®, Gentex® and Wheelock ® notification appliances. The PE series goes even further to make retrofits easier with the
advanced QuadraSync feature which allows notification appliances from different manufacturers to sync with each other. You
also have the option to monitor an existing circuit by placing a reference resistor of the same value on the power supply and
continuing to monitor the circuit without changing the field EOL.
Product Code: 0200-03460
The Hochiki SPC-24 Projected Beam Smoke Detector consists of an emitter and receiver. The SPC-24 detector should be placed so that smoke generated by a fire will likely rise into the path of the beam. The receiver is constantly monitoring and measuring the intensity of the beam transmitted by the emitter. Should the smoke from a fire cause a decrease in the signal strength of a magnitude that exceeds the programmed obscuration setting, an alarm signal is generated.
SKU: DCP-DIMMCategories: Addressable, HOCHIKI, Modules
Usage/Application |
Industrial
|
Number of Zone |
10
|
Material |
Sheet Metal
|
Operating Voltage |
24 V DC
|
Product Code: SCI (0400-01079)
The DCP-SCI short circuit isolator should be located between any devices on the SLC loop. In the event of a short on the SLC loop, the two adjacent isolators (closest isolators to the left and right of the shorted section) will activate and their respective LED indicators will be turned on. All devices between the active short circuit isolators will lose communication. This will prevent entire loop failure. Upon removal of the short condition, the DCP-SCIs will automatically restore the entire loop to the normal operating state.
Product Code: 0500-05890
The Hochiki HEH Series Horn
99 in stock
Current Rating | 2 Amps |
Brand | HOCHIKI |
Operation Mode | Automatic |
Contact Current Rating | 2 Amps |
Maximum Switching Current | 2 Amps |
- HOCHIKI R2ML-I – Dual Relay Module 2 AMPS
- #1 Supplier for Fire Safety Equipment in North America. Our company is dedicated to help and supply your fire equipment needs with the best prices Worldwide.
- We have the most dedicated customer service team to help you with any question regarding our products and your orders.
Model TS-0310/ TS-0310A
Microphone type Electret condenser microphone
Microphone directivity Cardioid
Frequency response 80Hz~16KHz
99 in stock
Product Code: 0500-06100
TheHochiki HCC Series Horn Strobe
89 in stock
Reviews