ALO-V Intelligent Analog Photoelectric Smoke Sensor-Asian-technologies-ltd
STANDARD FEATURES
• UL 268 7th Edition Listed
• Designed to resist unwanted alarms from cooking
and other nuisance alarm sources
• Optical particulate identification
• Early fire smoke detection
• 360° view of detector status LED
• Programmable non-polling LED
• Vandal resistant security locking feature
- Size Guide
Size Guide
DRESSEST-SHIRTBOTTOMSDRESSESSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
T-SHIRTSize Chest Waist Hips 2XS 32 26 32 XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 All measurements are in INCHES
and may vary a half inch in either direction.
BOTTOMSSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
- Delivery & Return
Delivery
Store delivery FREE
1-3 working days
Home or collection point from £35.00 FREE
On all your orders for home or collection point delivery
Returns
Return
We will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period).
Returns in store FREE
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
APPLICATION
The ALO-V (UL 268 7th edition listed) is a reliable, high quality multi-criteria Photoelectric Smoke Detector. It can be used
in all open areas where Photoelectric Smoke Detectors are
required. This detector is also suitable for monitoring smoke in
HVAC ducts. The newly developed “multi-spectrum smoke
categorization technology” detects smoldering and flaming
fires fueled by traditional materials and polyurethane while
reducing nuisance alarms.
The ASB7, ASBL7, SCI-B47, SCI-B67, YBN-NSA-47, and
HSB-NSA-67 bases are UL Listed with the ALO-V.
OPERATION
The construction of the new chamber enhances the smoke
entry for early fire smoke detection. The detection chamber
utilizes light from IR and Blue LED sources. In the event of
fire, particles of smoke enter the chamber and scatter light in
proportion to the smoke density, resulting in an increased
analog smoke measurement. The chamber contains a unique
baffle design which allows smoke to enter the chamber while
preventing external light from affecting the photodiode detector.
When the smoke density exceeds the programmed sensitivity
threshold, the detector transmits an interrupt to the fire alarm
control panel indicating a fire condition. The fire alarm control
panel automatically adjusts the detector threshold to compensate for contamination.
Up to 127 devices are permitted on each SLC loop. The detector address is set by using a model AP7 hand-held programmer. The detector can mount to a variety of bases including electronics-free 4 and 6 inch bases, relay bases, and
sounder bases. The detector’s status LED is viewable on the
main face of the detector from all directions.
DETECTOR SPACING
Smoke detector spacing shall be in compliance with NFPA 72.
For smooth ceilings and in the absence of specific performance-based design criteria, the distance between smoke
detectors shall not exceed a nominal spacing of 30 ft. (9.1m)
or all points on the ceiling shall have a detector within a distance equal to or less than 0.7 times the nominal 30 ft. (9.1m)
spacing. Detectors shall be located within a distance of onehalf the nominal spacing, measured at right angles from all
walls or partitions extending upward to within the top 15 percent of the ceiling height. For additional instructions see NFPA 72.
5 |
|
0 |
4 |
|
0 |
3 |
|
0 |
2 |
|
0 |
1 |
|
0 |
Related Products
- Make: Hochiki America
- Model code: ALN-V
- Type: Smoke
- Style: Photoelectric
- Hochiki America is a photoelectric smoke sensor with the following features: • Low profile – Only 2.00″ high, including base• Simple and reliable device addressing• Automatic compensation for sensor contamination• Built-in fire
Product Code: 0200-03460
The Hochiki SPC-24 Projected Beam Smoke Detector consists of an emitter and receiver. The SPC-24 detector should be placed so that smoke generated by a fire will likely rise into the path of the beam. The receiver is constantly monitoring and measuring the intensity of the beam transmitted by the emitter. Should the smoke from a fire cause a decrease in the signal strength of a magnitude that exceeds the programmed obscuration setting, an alarm signal is generated.
Product Code: 0500-05890
The Hochiki HEH Series Horn
99 in stock
Analogue Addressable Smoke detector
Country of Origin: GERMANY
Categories: Addressable Fire Alarm System, Fire Alarm System, Smoke/Heart Detector
The DCP-AMS are the Hochiki America series of addressable manual pull stations that provide a fast and practical means of manually initiating a fire alarm signal. Both single action and dual action manual pull stations are available. Resetting of the pull station requires either a 1/8″ hex key.
99 in stock
Product Code: 0500-06100
TheHochiki HCC Series Horn Strobe
89 in stock
Customization: | Available |
---|---|
Color: | Grey |
Type: | Simultaneous Interpretation System |
- Extended monitoring area
- Transmitter, receiver, and evaluating unit integrated into a compact housing
- Electronic help for detector alignment and automatic detector calibration procedure
- Automatic compensation for contamination
- LED display in control unit for various operating states
- Adjustable alarm thresholds
75 in stock
100 in stock
Product Code: OTC2367
The T-6702 is a full-duplex network audio paging microphones, built-in one-way and two-way communication system. This paging microphone could be installed anywhere on the LAN system. The T-6702 network paging microphone has several paging modes include zone paging, group paging, all zone paging, two-way intercom, conference system, discussion system & voting system.
The T-6702 is built-in an LCD to display program status and its IP address, the end-user is accessible to change the IP setting with a password. It is built-in a 1W speaker with excellent sound clearance so as to ensure the communication is smooth and clear. This microphone design is adopted advanced technology to avoid echo noise and to avoid data delay as well.
65 in stock
Usage/Application |
Industrial
|
Number of Zone |
10
|
Material |
Sheet Metal
|
Operating Voltage |
24 V DC
|
Reliable operation, even if the lens is contaminated by a film of oil, dust, water vapor or ice MOD. 016589
Reviews